Fixed and automated
Dust suppression systems: mist cannons, sprinklers and dust monitors
Wherever the mine is, 88Chemco designs and supplies dust suppression systems for mines and plants, then fits, commissions and supports them: mist cannons, sprinkler lines, the controller that switches them, and dust monitors that tell you whether they are working. They are the fixed partner to our dust suppressants: the system puts the water where the dust starts, and the product makes the water do more.
Where it fits
Where a fixed system beats a water cart, and where it does not
A fixed system fits where material moves
- Transfer points, chutes and conveyor discharge.
- Crushers, screens and tipping points.
- Active stockpiles that are built and reclaimed every day.
- Plant roads and yards inside the fence, where a cart cannot keep up.
- Blasting areas, where a mist cannon knocks the dust out of the air.
Not on haul roads
Haul roads are long and move with the pit. There a water cart and a road binder do more than any fixed line: Haul road dust control: choosing a method compares water alone, Hydrogel and the DustBinders, and Water cart equipment covers the cannons, spray valves and Ground Speed control on the cart.
Not on ground left standing
A tailings storage facility, an ash dump or a heap that is not worked needs a crust, not a daily wetting: see DustSkin.
Mist cannons
Mist cannons (fog cannons)
A mist cannon blows a fine mist of water from a fan, on a fixed or mobile stand, often turning from side to side. The droplets are small enough to catch dust in the air, where a sprinkler only wets the ground. A cannon is chosen for its reach, the size of its droplets, its water and power needs, and how it is moved: on a fixed post at a transfer point, on a trailer for a tip or a blast, or on a tower over a stockpile.
- Switching: by hand, on a timer, from the plant’s own control, or from a dust reading.
- Water: clean water, or water dosed with a wetting agent where the material sheds plain water.
- Coal and other hazardous areas: a site that needs explosion-protected equipment gets it; we check what your area classification asks for before we quote.
Sprinkler lines
Sprinkler lines on stockpiles, conveyors and plant roads
Fixed sprinklers wet a stockpile, a conveyor route or a plant road on a schedule, without sending a truck. A line is laid out from the site’s plan: where the dust starts, where the wind takes it, and where water may and may not fall. Each zone runs on its own valve, so the system waters the part that needs it and leaves the rest.
- On a timer, for steady work such as a stockpile reclaimed on shifts.
- On dust readings, so a zone comes on when a monitor near it reads high, and goes off when the reading falls.
- On the weather, so the system waters more in hot, dry wind and less after rain.
Control and data
The control that runs it, and the record it keeps
The control ties the cannons, valves, pumps and monitors together. It switches each zone, logs when it ran and how much water it used, and shows both on a screen for the plant and the environmental team. Where a wetting agent is used, a dosing pump adds it to the water at the rate set with you.
The record is what an environmental officer needs: when each zone ran, what the monitors read before and after, and how much water went down. We tell you where the data is kept and who can see it before you sign.
The control panels and instruments behind the system are covered on Mine technology services, under EC&I.
Dust monitoring
Real-time dust monitors for mines
A dust monitor reads the dust in the air where it stands and sends the reading as it happens. Placed at the fence, beside a crusher or downwind of a stockpile, monitors show where dust starts, whether the system is holding it, and when to switch a zone on.
Which measurement a site needs, such as fine particles (PM10 or PM2.5) or total dust, and how it must be measured, is set by its permit and the rules where the mine is. We check that the monitor suits that measurement before we quote, and we say so in the quote.
The system and the product
The system and our dust suppressants
- SuperWetter carries the water into coal and other dense heaps and holds the moisture in, through cannons or spray systems. On coal, it lowers the risk of spontaneous combustion.
- DustSkin crusts the surface of a heap that is no longer worked, so the system can stop watering it; we confirm with you how it is applied.
- Hydrogel holds water on a watered surface for longer, so each watering lasts longer between runs; we confirm with you how it is applied.
Tell us the product and the system, and we confirm with you how the product goes on. For the choice between wetting a heap and crusting it, read Stockpile and tailings dust: wet it, or bind it?, and for every type of product, Dust suppression chemicals: which type does what.
How a job runs
From survey to support
- Survey. On site, or from your plans, photos and video: where the dust starts, the wind, the water and the power.
- Design and quote. The cannons, lines, control and monitors, laid out on your plan. The quote says what is done, by when, and what your side provides.
- Supply, fit and commission. The equipment is delivered, fitted and set to work with your plant. Your site’s own registered electricians connect and sign off the electrical work.
- Train. Your operators and environmental team learn to run the system and read its record.
- Support. Service, spares and changes as the plant changes.
What we need from you
A site plan with the dust sources marked, the water supply and its pressure, the power available, the material handled, your dust permit or the limits you work to, and any hazardous area classification.
Rules we check
We check your dust permit and its measurement, the water you may use and where it may run off, the electrical sign-off on your site, and any hazardous area rules, before we quote.
Questions
Questions about dust suppression systems
Where does a fixed mist cannon do better than a water cart?
At a fixed source where material moves: a transfer point, a crusher or a stockpile worked every day. Haul roads are long and move with the pit, so they stay with the water cart.
Can a dust monitor turn the sprinklers on and off?
Yes. A zone comes on when the monitor beside it reads high and goes off once the reading drops; it can also run on a timer or by hand.
Which 88Chemco products can go through a fixed spray system?
SuperWetter, through a dosing pump: it is made to go into a spray system’s water. For our other products we confirm with you how they are applied on your site.
Will the monitor give readings our permit accepts?
Your permit and the rules where the mine is set what must be measured and how. We check that the monitor meets that before we quote, and say so in the quote.
Can a mist cannon be used at a coal stockpile?
Yes, with the equipment your area classification asks for. On coal, SuperWetter in the water carries it into the heap.
Contact
Tell us what you need.
Tell us the product, the quantities, the mine or site and its country, and the date you need it. Holding an RFQ or tender? Send it whole, and we reply to every line we supply.
E-mail info@88chemco.com · WhatsApp +27 84 556 8888 (opens WhatsApp)
Prices and deliveries outside South Africa are quoted with each order.